Introduction
A digital radiograph can look clean on screen and still fail to show the flaw an inspection is supposed to catch, for reasons that have nothing to do with exposure technique or operator skill. Three measurable properties of a digital or computed radiography image determine whether a given flaw is actually detectable: how strong the real signal is compared to background noise, how much contrast a real feature creates against its surroundings once noise is accounted for, and how finely the imaging system can resolve two closely-spaced details as distinct from each other. These are signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and basic spatial resolution (SRb) — and digital radiography standards control them because a technically well-exposed image can still miss a flaw if any one of the three falls short.
Caption: SNR, CNR and basic spatial resolution at a glance. Original diagram.

In practice, the weld standard ISO 17636-2 states its digital image quality requirements as three things: a minimum normalized SNR (SNRN) for the detector or plate, minimum IQI readings, and a limit on image unsharpness or basic spatial resolution. CNR is a defined image-quality metric used to understand visibility and to evaluate detectors, but it is not given as a minimum in ASTM E2698.
Signal-to-noise ratio and contrast-to-noise ratio
Signal-to-noise ratio (SNR) compares the level of a desired signal to the level of background noise, typically measured over a region of interest (ROI) in the digital or computed radiograph. A higher SNR means the real signal stands out more clearly against the image’s inherent noise — noise that comes from the detector itself, the exposure dose, and the imaging chain, not from the part being inspected.
Definitions as the standards give them
Quantity | Definition | What it depends on |
|---|---|---|
SNR | Mean signal intensity divided by the standard deviation of the intensity (the noise) | Radiation dose and the properties of the digital detector array (ASTM E2736, E2737) |
Normalized SNR (SNRN) | SNR measured, multiplied by 88.6 µm and divided by the basic spatial resolution SRb | The detector or plate, the dose, and the SRb of the image |
CNR | Difference of the mean signal levels of two image areas, divided by the standard deviation of the signal levels | Radiation dose and quality, object thickness and attenuation, and detector properties (ASTM E2698, E2737) |
SRb (basic spatial resolution) | Half of the measured image unsharpness; the smallest geometrical detail that can be resolved without geometric magnification when measured on the detector | Pixel or grain size, scatter in the detector and geometry; measured with a duplex wire IQI |
Each of these is measured on linearized data. The ROI is placed on a uniform area of the image, and the software reports its mean and standard deviation. The size and position of the ROI are set by the procedure.
Contrast-to-noise ratio (CNR) is closely related but measures something slightly different: it reflects the local contrast a feature creates against its immediate background, as the difference between the mean signal of the feature area and the mean of its background, divided by the noise (the standard deviation), rather than raw signal magnitude. In practice this means CNR is the more direct predictor of whether a specific flaw — which shows up as a local grey-value difference, not an overall brightness change — will actually be visible.
SNR and CNR side by side
SNR | CNR | |
|---|---|---|
Question it answers | How strong is the signal compared with the noise? | How well does a feature stand out from its background compared with the noise? |
Formula | Mean signal ÷ standard deviation | (Mean of one area − mean of the other) ÷ standard deviation |
Where it is measured | A uniform region of interest | Two areas: the feature and its background |
Moves with | Dose, detector efficiency, averaging, filtering | Dose and also contrast, so voltage, thickness and the feature itself |
Used in the weld standard as | The basis of the normalized minimum SNRN | A defined metric; ISO 17636-2 states its requirement as IQI readings |
Typical use | Acceptance of the exposure; detector comparison | Judging whether a given flaw will be visible; detector evaluation |
A flaw that gives 3 % contrast is lost at a CNR below about 1 and is clear at a CNR of several, even though the SNR of the background is high in both cases. That is why a high SNR alone does not prove a flaw is visible, and why a low-contrast flaw needs more SNR than a high-contrast one.
Both values respond to the same practical levers: lowering tube voltage (kVp) generally increases image contrast, while a higher exposure dose (more current, longer time or more averaged frames) lowers the relative noise. Dose acts mainly through the noise and voltage mainly through the contrast, so a change in either one moves both SNR and CNR, and the two levers can pull against each other: a lower voltage raises contrast but passes fewer photons, so more dose may be needed to hold the noise. Detector type (digital detector array/flat panel vs. computed radiography phosphor plate), total dose, and image processing (averaging, filtering) all influence both values, which is why they’re measured and specified as acceptance criteria rather than assumed from exposure settings alone.
The table below shows how each lever moves contrast, SNR, CNR and SRb.
Lever | Contrast | SNR and CNR | SRb |
|---|---|---|---|
Lower the tube voltage | Rises | Contrast rises; fewer photons pass, so noise may rise | Little change from the detector itself |
Raise dose (current, time) | No change | Noise falls, SNR and CNR rise | No change |
Average more frames or apply filtering | No change | Noise falls, SNR and CNR rise | Can blur if filtering is heavy |
Detector with smaller pixels | No change | Less signal per pixel, so SNR falls | Finer, SRb improves |
Geometry (source size and distances) | No change | No change | Adds geometric unsharpness to the image value |
Normalization: why SNR alone is not compared between detectors
A detector with larger pixels collects more photons per pixel, so it reports a higher SNR even though it resolves less detail. To compare detectors or plates fairly, ASTM E2736 and ISO 17636-2 normalize the measured SNR to a basic spatial resolution of 88.6 µm: SNRN = SNR × 88.6 µm ÷ SRb. The same measured SNR of 100 becomes an SNRN of 177 at an SRb of 50 µm, and 44 at an SRb of 200 µm.
Basic spatial resolution (SRb)
SNR and CNR both measure contrast sensitivity — whether the image can show a given density difference at all. Neither measures a separate, equally important property: how finely the detector and geometry can resolve two closely-spaced fine details as distinct from each other, rather than as one blurred feature. That property is basic spatial resolution (SRb), and film radiography rarely needed to measure it because film’s own resolution is extremely fine and almost never the limiting factor. Digital detectors — computed radiography (CR) phosphor plates and digital detector arrays (DDAs) — have a finite, coarser pixel or phosphor-grain resolution that can itself become the limiting factor independent of contrast, which is why SRb became a standard digital-RT measurement.
SRb is measured with a duplex-wire image quality indicator, governed by ISO 19232-5 (successor to EN 462-5). A duplex IQI consists of pairs of wires of decreasing diameter and decreasing spacing between each pair. The reader finds the pair that can no longer be separated. In a digital image that is the wire pair with the largest diameter whose dip between the two wires is less than 20 % of the pair contrast. That pair gives the image unsharpness (twice the wire diameter), and SRb is half of the unsharpness, which equals the wire diameter d, typically in millimetres or micrometres. The wire-pair table below is taken from IQI manufacturers’ data; read your own IQI’s certificate and the current ISO 19232-5 for the exact figures.
Duplex wire pairs and their SRb values
Duplex wire | Wire diameter d (mm) | Unsharpness (mm) | SRb (mm) | Line pairs per mm |
|---|---|---|---|---|
D1 | 0.80 | 1.60 | 0.80 | 0.63 |
D2 | 0.63 | 1.26 | 0.63 | 0.79 |
D3 | 0.50 | 1.00 | 0.50 | 1.00 |
D4 | 0.40 | 0.80 | 0.40 | 1.25 |
D5 | 0.32 | 0.64 | 0.32 | 1.56 |
D6 | 0.25 | 0.50 | 0.25 | 2.00 |
D7 | 0.20 | 0.40 | 0.20 | 2.50 |
D8 | 0.16 | 0.32 | 0.16 | 3.13 |
D9 | 0.13 | 0.26 | 0.13 | 3.85 |
D10 | 0.10 | 0.20 | 0.10 | 5.00 |
D11 | 0.08 | 0.16 | 0.08 | 6.25 |
D12 | 0.063 | 0.13 | 0.063 | 7.69 |
D13 | 0.050 | 0.10 | 0.050 | 10.00 |
D14 | 0.040 | 0.08 | 0.040 | 12.50 |
D15 | 0.032 | 0.064 | 0.032 | 15.60 |
The IQI in ISO 19232-5 can have up to 13 wire pairs and is used effectively up to 600 kV; an IQI with more than 13 pairs is used effectively below 225 kV. Placed on the test object on the source side, the IQI gives the image unsharpness and image SRb. Placed directly on the detector, it gives the detector unsharpness and the basic spatial detector resolution, SRb of the detector (ASTM E2002).
Why this matters for flaw detectability
A real flaw has to clear all three thresholds to be reliably seen. If SNR is too low, the flaw’s signal is buried in background noise regardless of how much contrast it would otherwise create. If CNR is too low, the flaw doesn’t stand out from its immediate surroundings even if overall signal strength looks fine. If SRb is too coarse for the flaw’s size, two features that should appear as distinct (or a feature’s true edges) blur together and the flaw either disappears or is misjudged in size. This is why digital radiography standards control all three: ISO 17636-2 sets a minimum SNRN, minimum IQI readings and a limit on basic spatial resolution for a given exposure — rather than relying on a visual “does it look good” check or on film-era density-based criteria that don’t translate directly to a digital detector’s behavior.
Code minimums
The figures below are an excerpt for orientation. Which row applies depends on the radiation source, the penetrated thickness and the testing class, so read the current edition of the standard or your written procedure for a given job.
Standard | What it sets for digital image quality | Note |
|---|---|---|
ISO 17636-2 (welds) | Minimum SNRN by source and class (Tables 3 and 4), IQI readings, and maximum image unsharpness or SRb (Annex B) | Class A is basic and class B is improved; the user defines minimum SNRN or SNR for the acceptance of images |
ASTM E2698 (DDA) | Image quality levels from IQI visibility, from level 00 to level 3, with 2-2T as the default; the procedure must state the detector SRb, mode and gain | CNR is defined but no minimum is given |
ASTM E2737 (DDA stability) | Periodic tests of SNR, CNR, contrast sensitivity and basic spatial resolution on phantoms | Applies to the detector, not to a production image |
ISO 19232-5 (duplex wire IQI) | How to determine image unsharpness and SRb | Not an acceptance standard by itself |
Minimum SNRN, ISO 17636-2, steel, copper and nickel alloys (excerpt)
Radiation source | Class A | Class B |
|---|---|---|
X-ray up to 50 kV | 100 | 150 |
X-ray 50 to 150 kV | 70 | 120 |
X-ray 150 to 250 kV | 70 | 100 |
- The full table also covers higher voltages, Yb-169, Tm-170, Se-75, Ir-192, Co-60 and megavolt X-ray, with thickness breaks, and lists the metal-front screens. Table 4 covers aluminium and titanium.
- Where the SNRN is measured in the heat-affected zone or parent material, the table values are multiplied by 1.4, unless the weld cap and root are flush with the parent material. If the weld centre reaches the table value, no measurement beside the weld is needed.
- The measured SNRN may fall to 80 % or more of the table value if the required image quality is still reached and either the voltage is reduced to 80 % or less of the Figure 20 values or energy-resolving detectors are used for scatter reduction.
- If the detector is not sharp enough, the shortfall is compensated by raising the SNR and by reading one more IQI wire or step-hole value for each missing duplex wire pair.
Caption: Checking a digital exposure and choosing the lever. Original flowchart.

Practical tips
- Measure the SNR on linearized data in a uniform area, and in the weld centre unless the procedure says otherwise. Values next to the weld have a higher requirement.
- Report SNRN, not raw SNR, when comparing detectors or plates. The same SNR of 100 can be 177 or 44 SNRN depending on the SRb.
- Measure SRb with the duplex IQI on the detector for detector qualification, and on the object for the image value. Say which one a figure is.
- If SNRN is short, raise the dose, lengthen the exposure, or average more frames before changing anything else. If the IQI reading is short, a lower voltage raises contrast.
- Do not judge sharpness by eye. A crisp image on screen can still fail the SRb limit, and a soft-looking image can pass.
- Write the detector, mode, gain, voltage, SRb and the SNRN reached into the report, so the next exposure can be set up the same way.
Common misunderstandings
- Treating SNR and CNR as the same thing. They respond to the same levers (dose, kVp) but measure different properties — overall signal strength versus local feature contrast — and a specification that requires one does not automatically satisfy the other.
- Assuming a sharp-looking image has adequate spatial resolution. SRb is a measured, standard-referenced value from a duplex-wire IQI, not a subjective visual impression — an image can look crisp on screen and still fail a specified SRb requirement.
- Checking SNR/CNR but skipping SRb (or vice versa) in digital procedures. Contrast sensitivity and spatial resolution are independent: a digital-RT exposure can pass on contrast sensitivity while failing spatial resolution, so a complete acceptance check verifies all three against the procedure’s specified minimums, not just the ones that are easiest to eyeball.
Key takeaways
- SNR measures overall signal strength against background noise; CNR measures how far a feature’s mean signal differs from its background, relative to the same noise — they respond to the same levers (dose, kVp) but measure different things.
- Basic spatial resolution (SRb), measured with a duplex-wire IQI per ISO 19232-5, captures a detector/geometry limitation that SNR and CNR cannot — digital detectors have a finite pixel/phosphor-grain resolution that film essentially never needed to worry about.
- A flaw must clear all three thresholds (SNR, CNR, SRb) to be reliably detected; passing on one doesn’t guarantee the others.
- Digital radiography standards control these properties because a visually clean image can still miss a flaw. ISO 17636-2 sets minimum SNRN values, IQI readings and an SRb limit; ASTM E2698 applies image quality levels and defines CNR but sets no minimum CNR; ASTM E2737 evaluates detectors with them.
- The numeric minimums depend on radiation source, thickness and class. Take the exact figures for a job from the current edition of the standard or the written procedure; the Code minimums section gives an excerpt.
- IQI in Radiographic Testing: Wire vs Hole Types — the wire, hole and duplex IQIs used to read image quality and basic spatial resolution
- Qualifying Digital Radiography: ASME, ISO 17636-2 and ASTM — how a CR or DDA technique is qualified against the codes that set these limits
- Film vs CR vs DR: Decision Guide — choosing between film, phosphor plates and digital detector arrays for a job
References
- ISO 17636-2:2022, Non-destructive testing of welds — Radiographic testing — Part 2: X- and gamma-ray techniques with digital detectors. Clause 7.3.1 and Tables 3 and 4 give the minimum SNRN values; the annexes give the IQI and unsharpness requirements.
- ISO 19232-5:2018, Non-destructive testing — Image quality of radiographs — Part 5: Determination of the image unsharpness and basic spatial resolution value using duplex wire-type image quality indicators (successor to EN 462-5).
- ASTM E2736, Standard Guide for Digital Detector Array Radiography — defines SNR, CNR and normalized SNR (SNRN).
- ASTM E2698, Standard Practice for Radiographic Examination Using Digital Detector Arrays — image quality levels and the written-procedure requirements for DDA examination. Check the current edition.