Wire vs Hole IQIs and Duplex IQIs for Digital Images

Wire vs Hole IQIs and Duplex IQIs for Digital Images

Sources - Photos: Dominik Tobel, the blowup / Unsplash

0

Table of content

Why IQIs matter

A radiograph can look sharp and well-exposed and still fail to show a flaw that matters — the only way to know whether an image is actually good enough to trust is to put a known reference object in the shot and check whether it shows up the way it should. An image quality indicator (IQI) is exactly that reference: a small, standardized object of known material and dimensions, placed on the source side of the test object (or per the technique specified) before exposure, whose visibility in the finished radiograph tells the inspector how sensitive that particular exposure actually was. If the IQI’s smallest required feature isn’t visible, the radiograph doesn’t meet the specified sensitivity — regardless of how the image looks to the eye — and the exposure has to be redone. Different IQI designs measure different things: some test whether the image can show a small density/contrast difference at all, and a separate design tests whether the imaging system can resolve two closely-spaced fine details as distinct from each other. Knowing which design does which, and which one a given code or procedure actually calls for, is the practical core of this guide.

Four IQI designs and what each reports: wire, hole plaque, step-hole and duplex wire

Four IQI designs and what each reports. Original diagram.

Wire-type vs. hole-type IQIs

Two IQI designs dominate radiographic practice, and they come from two different standards traditions — which one a procedure calls for usually follows directly from which code governs the job.

1. Selection: the order of decisions

  • Start with the governing code or client procedure. It states the IQI type, the required wire or hole for each thickness range, and how the result is reported.
  • Match the IQI material to the test object. ISO 19232-1 IQIs come in material groups FE, CU, AL and TI, and all wires in one IQI are the same material. ASTM IQIs use material groups 1 to 5 for heavy alloys and 01 to 03 for light metals.
  • Pick the size so the required element sits inside the IQI. A wire IQI is chosen so the required wire number is among its seven wires; a hole IQI is chosen by plaque thickness.
  • Add a duplex wire IQI where the procedure calls for a spatial resolution value, which it does for digital detectors.

Flowchart for choosing the IQI: the governing code or client procedure decides between hole-type, wire-type and an added duplex wire IQI

Choosing the IQI. Original flowchart.


Type

Standard

Design

Reported as

Usual home

Wire

ISO 19232-1; ASTM E747

Seven parallel wires in a holder, from a series of 19 (ISO)

Wire number of the thinnest visible wire, such as W10

ISO and EN work; also accepted in ASME as the essential wire

Hole-type (plaque)

ASTM E1025 (SE-1025)

Thin plaque with three holes at 1T, 2T and 4T

Level such as 2-2T

ASTM and ASME work

Step-hole

ISO 19232-2

Steps with holes

Image quality value from the visible holes

Common in France; used in some European procedures

Duplex wire

ISO 19232-5

Wire pairs of decreasing diameter and spacing

First pair not resolved: unsharpness and SRb

Digital radiography

ISO 19232-1:2013 extends the wire IQI standard to digital detectors (it replaced "film" with "detector") and adds an annex for converting ASTM wire identities to ISO wire numbers. ASTM E747 sets the wire IQI at the 2-2T level of E1025 unless purchaser and supplier agree otherwise.

Wire-type IQIs are the convention under ISO/EN practice, governed by ISO 19232-1 (the direct successor to EN 462-1), with ASTM E747 as the equivalent North American standard for design, manufacture, and material grouping of wire IQIs. A wire IQI is a set of parallel wires of decreasing diameter embedded side by side in a flat plastic holder. Sensitivity is read as the thinnest wire that is clearly visible in the finished radiograph, reported as a wire number against the standard’s own designation system.

Hole-type (plaque) IQIs are the conventional choice under ASTM/ASME practice, governed by ASTM E1025, which ASME adopts as SE-1025 in Section II and calls up in Section V, Article 2 (Boiler and Pressure Vessel Code). A hole-type IQI is a thin metal plaque with three drilled holes, each sized as a multiple of the plaque’s own thickness — commonly 1T, 2T, and 4T, where T is the plaque thickness. Plaques thinner than No. 10 are an exception, with fixed 0.010, 0.020 and 0.040 in. holes. Sensitivity is reported as a designation such as “2-2T,” meaning a plaque with thickness equal to 2% of the material’s thickness, with its 2T hole visible in the radiograph.

2. The ISO wire series

The ISO series has 19 wires, W1 to W19. They are split into four overlapping IQIs of seven wires each: W1 to W7, W6 to W12, W10 to W16 and W13 to W19, with wire lengths of 10, 25 or 50 mm. A full designation reads like IQI ISO 19232-1 W10 FE-25.

ISO 19232-1 wire series: 19 wire diameters from W1 at 3.2 mm to W19 at 0.05 mm in four overlapping seven-wire sets

The ISO 19232-1 wire series. Original chart from published wire diameters.

3. Sensitivity: how to read the result

  • Wire IQI: the image quality value is the wire number of the thinnest wire that can be detected on the radiograph.
  • Hole IQI: the level 2-2T means the plaque is 2 % of the specimen thickness and the 2T hole must be visible. Level 2-1T needs the 1T hole, and 2-4T the 4T hole.
  • Equivalent sensitivity expresses the result as the IQI thickness, as a percentage of the part, at which the 2T hole would show: 1.4 % for 2-1T, 2.0 % for 2-2T and 2.8 % for 2-4T. ASTM E2698 uses image quality levels with equivalent sensitivities from 0.7 % to 2.8 %.
  • Read the result against the value in the procedure for that thickness and technique. A better result than required passes; a worse one fails, however good the image looks.

Hole-type IQI plaque with 1T, 2T and 4T holes on a test object, and a table of levels 2-1T, 2-2T and 2-4T with equivalent sensitivity

How a hole-type level such as 2-2T is built. Original diagram.

The practical takeaway: ASTM/ASME practice conventionally specifies hole-type plaques; ISO/EN practice conventionally specifies wire-type IQIs. Either system can technically be called out by either code family depending on the specific procedure in force, so the governing code or client specification — not habit — is what should decide which IQI type goes on a given job.

4. Placement

  • Source side is the default. The IQI sits on the side of the object facing the source, because it then shows the image as the beam forms it, including geometric unsharpness.
  • Where the source side is not accessible, the IQI is placed on the film or detector side in contact with the part, with a lead letter F next to it. ASME Table T-276 gives separate film-side values, so the required wire or hole for that case differs from the source-side one.
  • Where the part cannot carry the IQI, ASME allows a separate block of the same material. The IQI sits on the source side of the block, the block is as close as possible to the part, and for hole IQIs the block is large enough that at least three sides of the IQI image are visible.
  • Check the placement rule for the technique in use. Double-wall techniques, small pipe and tubes have their own rules in the code.

IQI placement: source side (preferred) and detector side with a lead letter F when the source side is not accessible

Source-side and detector-side IQI placement. Original schematic.

Duplex-wire IQIs and digital spatial resolution

Wire-type and hole-type IQIs both report image sensitivity: can the image show a small thickness difference at all. That reading depends on contrast, noise and unsharpness together. That was the right thing to measure for film, because film’s own spatial resolution is extremely fine and essentially never the limiting factor in what a radiograph can show. Digital detectors are different: computed radiography (CR) phosphor plates and digital detector arrays (DDAs/flat panels) have a finite, coarser pixel or phosphor-grain resolution that can itself become the limiting factor for seeing fine detail, independent of contrast. A conventional wire or hole IQI can’t isolate or quantify that geometric/spatial limit, because its reading blends contrast, noise and unsharpness.

That separate measurement is basic spatial resolution (SRb), governed by ISO 19232-5 (with EN 462-5 as its historical European predecessor, now superseded). A duplex-wire IQI consists of pairs of wires of decreasing diameter and decreasing spacing, each pair closer together than the last. The reader’s job is to find the pair that can no longer be separated: in a digital image, the wire pair with the largest diameter whose dip between the two wires is less than 20 % of the pair contrast. That pair’s wire diameter d gives SRb, and the image unsharpness is 2d. The full wire-pair table is in the SNR, CNR and SRb guide; read the figures for your own IQI from its certificate and the current ISO 19232-5.

Duplex-wire IQIs are specified alongside, not instead of, a conventional wire or hole IQI in digital radiography procedures — the two measure different properties (contrast sensitivity vs. spatial resolution) and a complete digital-RT image-quality check verifies both.

Digital-specific requirements

  • Detector-side limits. Digital detectors are limited by pixel or grain size, so the standards ask for an SRb value as well as an IQI reading.
  • ISO 17636-2. Clause 6.7 covers the types and positions of IQIs, including duplex wire IQIs and single wire or step-hole IQIs, with evaluation criteria for digital grey-value images. The minimum IQI values, normalized SNR and SRb limits are set together, and a shortfall in one can be offset in another under its compensation rules.
  • ASTM E2698. The procedure must state the detector SRb, the mode and the gain, and image quality levels from 00 to 3 use hole IQI visibility, with 2-2T as the default.
  • ASME Section V, Article 2. Mandatory Appendix III covers digital image acquisition, display and storage for radiography.
  • Where the duplex IQI goes. On the object it gives the image unsharpness and SRb; on the detector it gives the detector SRb (ASTM E2002). The ISO duplex IQI has up to 13 pairs and works up to 600 kV; a version with more than 13 pairs is used below 225 kV.
  • Order of effort. If the IQI reading is short, check noise first (raise dose or average frames), then contrast (lower voltage), then unsharpness (detector and geometry). The SNR, CNR and SRb guide covers each.

Contrast, noise and unsharpness all feed the IQI reading, while the duplex wire IQI reads unsharpness alone

Why digital procedures add a spatial resolution check. Original diagram.

Practical guidance for RT Level II technicians

  • Check the procedure before reaching for an IQI. ASTM/ASME-governed work expects a hole-type plaque and reports sensitivity as a “source%-hole” designation (e.g., 2-2T); ISO/EN-governed work expects a wire-type IQI and reports sensitivity as a wire number. Using the wrong family’s IQI, or reporting sensitivity in the wrong convention, is a procedure nonconformance even if the image itself is technically fine.
  • Placement matters as much as type. An IQI is placed on the source side of the test object per the governing procedure (film-side or detector-side placement is used only when source-side access isn’t possible, is marked with a lead letter F, and is read against its own required value in the procedure) — check the placement rule in the procedure rather than assuming.
  • A digital procedure likely wants both an IQI reading and a spatial resolution value from a duplex-wire IQI. Whether the duplex IQI is in every production exposure or in a reference exposure is set by the procedure. The conventional IQI verifies contrast sensitivity; the duplex-wire IQI verifies the detector/geometry’s spatial resolution. Neither substitutes for the other, and a digital radiography procedure that specifies only one is likely missing a required check.
  • Reading sensitivity isn’t a pass/fail glance. The specific hole, wire, or wire-pair that must be visible is itself specified by the procedure (based on material thickness and technique), so “sensitivity achieved” is only meaningful against that procedure’s own required value — not against a general rule of thumb.

Common misunderstandings

  • Treating “IQI” as one single thing. Wire, hole, and duplex-wire IQIs measure different properties and are governed by different standards; a procedure that just says “use the IQI” without specifying which type leaves real ambiguity.
  • Assuming a duplex-wire IQI is a backup or alternative to a conventional IQI. It isn’t — it measures spatial resolution, a property a conventional wire or hole IQI cannot isolate. Digital procedures generally need both.
  • Reading sensitivity against a remembered number instead of the actual procedure’s requirement. The required hole/wire/wire-pair to be visible depends on material thickness and technique as specified in that job’s procedure, not a fixed rule of thumb carried over from a different job.

Checks before you accept the image

  • Is the IQI the type, material and size the procedure names?
  • Is it on the side the procedure requires, and does it carry an F if it is on the detector side?
  • Is the required wire, hole or step visible, and is it read against the value for this thickness and technique?
  • For digital work, is the SRb value and the normalized SNR on the report, and are they inside the procedure limits?

Key takeaways

  • Wire-type IQIs (ISO 19232-1 / ASTM E747) are the ISO/EN convention; hole-type plaque IQIs (ASTM E1025, used by ASME Section V) are the ASTM/ASME convention — the governing code decides which one a job uses.
  • Wire and hole IQIs report overall image sensitivity, which blends contrast, noise and unsharpness; they cannot isolate spatial resolution.
  • Duplex-wire IQIs (ISO 19232-5 / EN 462-5) measure basic spatial resolution (SRb) — a property unique to, and critical for, digital/computed radiography detector qualification.
  • A complete digital-RT image-quality check generally needs both a conventional IQI and a duplex-wire IQI; whether the duplex IQI is in each exposure or a reference exposure is set by the procedure. One does not substitute for the other.
  • Always read sensitivity against that job’s own procedure requirement, not a remembered figure from a different job or material thickness.

Related reading on OneStopNDT

References

  1. ISO 19232-1, Non-destructive testing — Image quality of radiographs — Part 1: Image quality indicators (wire type) — determination of image quality value (successor to EN 462-1).
  2. ASTM E747, Standard Practice for Design, Manufacture, and Material Grouping Classification of Wire Image Quality Indicators (IQI) Used for Radiology.
  3. ASTM E1025, Standard Practice for Design, Manufacture, and Material Grouping Classification of Hole-Type Image Quality Indicators (IQI) Used for Radiology; referenced by ASME Section V.
  4. ISO 19232-5, Non-destructive testing — Image quality of radiographs — Part 5: Determination of the image unsharpness and basic spatial resolution value using duplex wire-type image quality indicators (successor to EN 462-5).
  5. Baker Hughes/Waygate Technologies NDT blog, “What are common Image Quality Indicators (IQIs)?,” and ASTM E2002 (Standard Practice for Determining Total Image Unsharpness and Basic Spatial Resolution in Radiography and Radioscopy) — corroboration that duplex-wire IQIs are tied to digital radiography’s needs and that spatial resolution is a distinct measurable quantity from contrast sensitivity.
  6. ISO 19232-1:2013, wire-type IQIs, overview
  7. ISO 19232-1:2013, preview text
  8. ISO 19232-5:2018, preview
  9. ASTM E1025-98, hole-type IQI levels and equivalent sensitivity
  10. ASTM E1025-18, preview
  11. ISO 17636-2:2022, overview
  12. Baker Hughes, What are common image quality indicators (IQIs)?
  13. Baker Hughes, The correct position to determine the image quality indicators
  14. Ewert and Zscherpel, Minimum requirements for digital radiography equipment
  15. ASME BPVC Section V, Article 2, T-233, T-276, T-277 and Mandatory Appendix III (current edition).

Frequently Asked Questions

What’s the difference between a wire IQI and a hole-type IQI?

They report the same thing, image sensitivity, using different physical designs and reporting conventions. Wire IQIs (ISO 19232-1/ASTM E747) use a set of parallel wires of decreasing diameter and report sensitivity as a wire number; hole-type plaques (ASTM E1025) use a plate with drilled holes sized relative to its own thickness and report sensitivity as a designation like “2-2T.” Which one you use follows the governing code, not personal preference.

Do I need a duplex-wire IQI if I’m already using a conventional IQI?

Generally yes, for digital radiography. A conventional IQI tells you whether the image can show a given contrast difference; a duplex-wire IQI tells you whether the detector/geometry can resolve two closely-spaced fine details as distinct from each other (spatial resolution). They measure different properties, and most digital-RT procedures specify both.

Why didn’t film radiography need duplex-wire IQIs?

Film’s own spatial resolution is extremely fine and essentially never the limiting factor in what a radiograph can show, so contrast sensitivity (measured by a conventional IQI) was the only practical limit worth checking. Digital detectors have a coarser, finite pixel or phosphor-grain resolution that can itself limit what’s visible, independent of contrast — which is why a separate spatial-resolution measurement became necessary.

What standard governs duplex-wire IQIs?

ISO 19232-5, with EN 462-5 as its superseded European predecessor.

What does 2-2T mean on an IQI?

The plaque is 2 % of the specimen thickness and the 2T hole, whose diameter is twice the plaque thickness, must be visible. It is equivalent to 2.0 % sensitivity.

What is W10 on a wire IQI?

W10 is the tenth wire of the ISO series, 0.40 mm in diameter. An IQI ISO 19232-1 W10 FE-25 holds wires W10 to W16 in steel with 25 mm wires.

Where do I place the IQI on a weld?

On the source side of the weld unless the procedure says otherwise, and on the detector side with a lead letter F only when the source side is not accessible. The code sets the position for each technique.

Can I use a wire IQI for an ASME job?

ASME Section V, Article 2 lists both hole-type and wire-type IQIs in its selection table. The procedure and the client decide which one a job uses.