Introduction
Identifying surface-breaking cracks before they cause a critical failure is essential to the safety and reliability of industrial assets. Alternating Current Field Measurement (ACFM) is a sophisticated technique for electromagnetic non-destructive testing (NDT) that can be used to locate and size surface-breaking cracks without removing coatings and without relying on calibration blocks for sizing. ACFM testing is commonly used in the power, rail, offshore, and oil & gas industries and is a rapid, dependable testing method for safety-critical components, with minimal downtime.
What is Alternating Current Field Measurement (ACFM)?
Alternating Current Field Measurement (ACFM) is one of the electromagnetic non-destructive testing methods employed for the detection and sizing of surface-breaking cracks in metallic components. It is most widely applied to ferritic steels, but with appropriate probes and settings it can also be used on austenitic stainless steels and other non-magnetic conductive alloys. It requires no electrical contact with the component, can inspect through most non-conductive coatings, and estimates crack length and depth using validated mathematical models rather than calibration blocks.
Note: This article uses the term ACFM to mean Alternating Current Field Measurement and not Actual Cubic Feet per Minute, which is an airflow measurement found in HVAC and compressor systems.
By combining electromagnetic theory with mathematical modelling, ACFM was developed to inspect safety-critical structures for the presence of fatigue cracks and stress corrosion cracks. A crack's existence and surface length can be found using Magnetic Particle Inspection (MPI), but its depth cannot be determined. In addition to detecting the crack, ACFM assesses both depth and length. It can also inspect painted or coated surfaces with very little preparation, which is beneficial in industries where stripping paint or coatings is expensive or impractical.
The Principle of ACFM

Both Alternating Current Field Measurement and conventional eddy current testing are based upon alternating electromagnetic fields, but they are based on different principles. In traditional eddy current testing, localized currents are created, and the change in coil impedance that results is measured. ACFM creates eddy currents as well, but instead of measuring coil impedance, it measures the magnetic field that results from applying a uniform alternating current to the component's surface. The inspection system then measures the disturbance of this current and the magnetic field caused by a crack that is present on the surface of the component.
Because of the skin effect, the alternating current concentrates near the material's surface, so the method is very sensitive to any defect on the surface. When a crack is encountered the current can't just go through the crack, it must flow around the crack. This alteration of the current path introduces the predictable distortion of the magnetic field over the crack.
An ACFM probe measures two magnetic field components: Bx, which is measured perpendicular to the induced current flow, and Bz, which is measured perpendicular to the inspection surface. A crack forces the current to flow deeper into the material, producing a reduction (trough) in Bx above the flaw whose amplitude correlates with crack depth. The current also flows around the flaw at both ends of the crack, producing a positive and a negative peak in Bz; the length of the crack is related to the distance between these peaks. These signals, when combined, create a unique butterfly plot that allows the inspector to confirm crack indications and better understand their characteristics.
The use of established mathematical models for crack sizing instead of calibration blocks is a significant advantage of ACFM. According to ASTM E2261, a reference block with slots of known dimensions is still utilized to confirm system operation both before and after an inspection, but it is not used to determine the actual crack size. The inspection software uses analysis of the measured Bx and Bz signal to directly estimate the crack length and depth. The model-based approach minimizes the time required for set-up, provides greater repeatability and allows for reliable inspections of coated materials; alternating current field measurement is an attractive solution for weld inspections and other components where safety is paramount.
ACFM and conventional eddy current testing both rely on alternating electromagnetic fields but work differently — see how standard eddy current testing detects defects for comparison.
→ Read: Eddy Current Testing Explained
How an ACFM Inspection Is Carried Out
The ACFM inspection starts with choosing an appropriate probe based on the component geometry and requirements of the inspection. The ACFM instrument, connected to the probe, generates the alternating current and records the resulting magnetic field signals. A scan is generally preceded by a check of the equipment settings and a confirmation that the inspection surface is reasonably clean. Paint and protective coatings need not be removed.
The inspection is made by moving the probe at a steady speed across the weld or component surface and continuously measuring the components of the magnetic field (Bx and Bz). Modern ACFM systems show these signals in real time, so inspectors can track the area for indications of cracks as the scan proceeds. The data from the inspections is also stored in dedicated software and can be used to create butterfly plots, assess crack dimensions and create digital inspection reports.
Unlike many conventional methods, ACFM not only identifies cracks but also estimates their length and depth. If the structure to be inspected is large or if it is a long weld, array probes can scan a larger area and increase the speed of the inspection. Cracks that are perpendicular to the induced current flow are the ones that ACFM is most sensitive to. When transverse cracks are an issue, a second scan is performed with the probe turned 90 degrees to the direction of the first scan, allowing the generated current to flow across the anticipated crack orientation.
Want to get certified in ACFM inspection? Check out the ACFM Level I course covering electromagnetic theory, probe operation, and signal interpretation for real-world inspections.
→ Read: Alternating Current Field Measurement (ACFM) Level I Course
Applications of ACFM
Alternating Current Field Measurement is commonly applied in industries where surface-breaking defects can threaten structural integrity. It is particularly useful for in-service inspections, as its ability to inspect through coatings means it does not require extensive surface preparation.
For welded structures, a typical application of ACFM testing would be to evaluate weld toes and heat-affected regions for fatigue cracking, which occurs during repeated loading conditions. It is especially well suited for offshore platforms and subsea structures, where conducting inspections underwater would be expensive and impractical. These structures can be evaluated in situ without removing the coating because ACFM penetrates the majority of coatings.

ACFM NDT is used in the oil and gas industry to detect fatigue cracks and stress corrosion cracking (SCC) in threaded connections, risers, pipelines, and pressure-containing components. It can be used in the railway industry to identify rolling contact fatigue in rail, switches and crossings before it becomes a safety concern. It can also be applied to assess the condition of tank cars, storage tanks, bridges and parts of power plants where early detection of cracking promotes preventive maintenance and avoids unplanned downtime. In order to evaluate vital assets while they are still in use, dedicated high-temperature probes also enable inspection of hot surfaces, sometimes as high as 500 °C, depending on the probe and system.
Advantages of ACFM
The biggest benefit of ACFM is the ability to examine through paint, protective coatings, light rust and scale, which means little surface preparation is required. This reduces inspection time, lowers maintenance costs and minimises disruption to plant operations.
Unlike many conventional methods, ACFM not only identifies cracks but also estimates their length and depth. This quantitative information aids the maintenance team to determine the severity of the defect and to decide on repairs. Because crack sizing is done mathematically, not by calibration blocks, inspections are easier to conduct and are more consistent.
ACFM is also suitable for underwater, offshore and in-service inspections which may be challenging or impracticable with conventional inspection methods. Modern ACFM instruments also include real-time data visualization, permanent digital record and automated reporting, which make inspections more efficient and add to traceability for asset integrity management.
Unlike ACFM, Magnetic Particle Inspection only gives a general crack indication — learn how MPI works and where it's best applied.
→ Read: Magnetic Particle Testing
Limitations: What ACFM Cannot Do
Alternating Current Field Measurement (ACFM) is an effective electromagnetic inspection method, however, not all defects and materials can be inspected with ACFM. It detects surface-breaking cracks only and cannot reliably find subsurface or embedded discontinuities.
The test is not suitable for detecting volumetric defects such as porosity, slag inclusions or internal voids, as these do not create the same surface current disturbances as open cracks. Because sizing assumes a semi-elliptical crack profile, ACFM offers only estimated length and depth and cannot determine crack inclination or angle. As a result, sizing of irregular or branched cracks may be less precise. Inspection performance also depends on the material type, probe orientation and surface condition. Practical detection capability is usually in the region of 5 mm crack length and 0.5–1.0 mm crack depth under favourable conditions. The achievable capability should be demonstrated for the particular application, as reported values differ between systems and techniques. It is important that inspectors recognise these limitations when choosing the most suitable NDT technique for a specific application.
Quick Reference Tables
Table 1. ACFM vs MPI vs Conventional Eddy Current Testing
Table 2. Common Applications of ACFM
Table 3. Typical Inspection Capabilities
*Actual detection capability depends on the material, probe type, surface condition, and inspection procedure.
Conclusion
Alternating Current Field Measurement (ACFM) is one of the most successful of the electromagnetic NDT methods for surface-breaking crack detection and sizing of safety-critical components. Its ability to inspect through coatings, estimate crack size using validated models rather than calibration blocks, and produce permanent digital inspection records make it a preferred choice across a variety of industries, including the offshore, oil & gas, rail, power generation and heavy engineering sectors. ACFM NDT cannot detect volumetric defects but its rapidity, reliability and quantitative crack sizing for surface-breaking defects is an invaluable tool for preventive maintenance and asset integrity management.
Frequently Asked Questions (FAQs)
What is the smallest defect that ACFM can detect?
Under favourable conditions, ACFM can typically detect surface-breaking cracks of approximately 5 mm length and 0.5–1.0 mm depth. The detection capability, however, will vary depending on the material, type of probe, surface condition, crack orientation and inspection procedure.
Can ACFM detect subsurface defects?
No, ACFM is specifically developed to measure the cracks on the surface. It is insensitive to volumetric and subsurface defects such as porosity, slag inclusions, laminations and internal voids. For such applications, techniques like Ultrasonic Testing (UT) or Radiographic Testing (RT) would be more suitable.
Is it possible to use ACFM under paint or with galvanised coatings?
Yes, One of the primary benefits of ACFM NDT is that many non-conductive coatings (such as paint and protective coatings) can be directly inspected without requiring removal. Because zinc is electrically conductive and might lessen sensitivity by carrying a portion of the induced current, galvanized coatings present a more difficult situation. ACFM can often still be applied through galvanising; however, performance depends on the thickness and quality of the coating and should be checked against the manufacturer's instructions and a reference block prior to inspection.
How is ACFM different from Magnetic Particle Inspection (MPI)?
Both methods detect surface-breaking cracks. MPI shows the crack's presence and surface length, but provides no depth information and requires clean, coating-free surfaces. ACFM testing can, however, provide an estimation of the length and depth of a crack, create digital inspection records and can frequently be used to inspect through a protective coating, with limited surface preparation.
What certification is required to perform ACFM inspections?
Inspectors are typically qualified either through third-party certification to ISO 9712, issued by an accredited certification body, or under an employer-based scheme such as one written to ASNT SNT-TC-1A. Certification requirements vary by industry, regulator and employer.
Which industries commonly use ACFM?
ACFM is used in the offshore, oil & gas, marine, power generation, railway, petrochemical & heavy engineering industry. It especially works well in the examination of welded joints, pipelines, pressure vessels, storage tanks, threaded connections and other areas that may be prone to fatigue failure or stress corrosion cracking.